PGR
TOOLMED
HPP
1 Pcs
5-15 Days
/
| Availability: | |
|---|---|
Product Description
The PGR Patellar Trochlear Groove Replacement Kit is specifically engineered to restore the patellofemoral articulation, improving patellar tracking and reducing anterior knee pain in patients with trochlear groove degeneration.
The kit includes anatomically shaped components designed to match the natural trochlear groove geometry, ensuring optimal articulation and joint biomechanics.
The system provides comprehensive instruments for accurate bone preparation, trialing, implant placement, and fixation, allowing surgeons to customize the procedure based on patient anatomy.
Implants are made from premium medical-grade materials with excellent wear resistance, corrosion resistance, and long-term durability to ensure reliable clinical performance.
The kit supports minimally invasive approaches to reduce soft tissue disruption, promote faster recovery, and minimize postoperative pain.
Ergonomically designed instruments enhance intraoperative accuracy, ease of handling, and reproducibility of the surgical technique.
Used for patients with isolated trochlear groove or patellofemoral compartment osteoarthritis causing pain and functional limitation.
Indicated for patients with trochlear dysplasia or recurrent patellar subluxation where anatomical reconstruction is required.
Applied in patients with persistent anterior knee pain or functional impairment despite non-surgical treatment.
Suitable for selected revision cases where patellofemoral joint restoration is necessary.
Recommended for use in orthopedic hospitals, knee surgery centers, and trauma units performing joint reconstruction procedures.

| Product Name | PGR Patellar Trochlear Groove Replacement Kit |
| Material | HPP |
| Certificate | CE Certificate |
| Brand | TOOLMED |
| MOQ | 1 Pcs |
| OEM | Avaliable |
| Package | PE Inner Bag+Carton |
| Payment Method | T/T,Bank transfer, Western Union |
| Delivery Time | 5-15 Days |
| Shipping | DHL EMS UPS TNT FEDEX |


The PGR Patellar Trochlear Groove Replacement Kit is an orthopedic surgical system designed for restoring the patellofemoral joint by replacing the trochlear groove and optimizing patellar tracking. It allows surgeons to reconstruct the anterior knee compartment with precision.
This kit is used for isolated patellofemoral osteoarthritis, maltracking, recurrent subluxation, and selected revision procedures where restoration of the trochlear groove anatomy is required.
The kit provides accurate anatomical reconstruction, enhanced joint biomechanics, and improved patellar tracking. Its modular instrumentation allows customization to individual patient anatomy and minimizes surgical complexity.
Replacing the trochlear groove restores the normal geometry of the patellofemoral articulation, balancing forces on the patella and femur. This helps reduce pain, improve joint stability, and prevent progressive cartilage wear.
After exposure of the anterior knee compartment, the damaged trochlear groove is prepared using precision cutting guides and reamers. Trial implants help confirm fit and alignment, followed by definitive component placement and fixation.
Postoperative rehabilitation protocols focus on early range of motion, quadriceps strengthening, and gradual weight-bearing as tolerated. Routine follow-up imaging ensures proper implant positioning and joint function recovery.
The PGR Patellar Trochlear Groove Replacement Kit is a reliable and precise solution for patellofemoral joint restoration. With anatomically contoured implants, modular instruments, and surgeon-friendly design, it provides effective treatment for trochlear groove degeneration and patellar maltracking.
It is used for patellofemoral osteoarthritis, trochlear dysplasia, recurrent patellar instability, and selected revision procedures.
The implants are made from medical-grade alloys and polyethylene for optimal durability and biocompatibility.
Yes, the instruments are designed to accommodate minimally invasive approaches when indicated.
Yes, trial implants are included to ensure accurate sizing and alignment before definitive implantation.
Patients with isolated patellofemoral joint degeneration, maltracking, or failed conservative management may benefit from this procedure.
Yes. All instruments are autoclavable and suitable for repeated use in surgical procedures.


We offer fast and reliable global shipping. Standard lead times range from 7 to 15 working days, depending on order quantity and customization requirements. Express delivery options are also available upon request.
Yes, we ship to most countries worldwide. We work with trusted logistics partners to ensure timely and secure delivery.
We accept a variety of payment options, including T/T (bank transfer), L/C, and PayPal for smaller orders. Payment terms can be discussed based on order volume and partnership agreements.
Yes, samples are available for evaluation. Please contact our sales team to request product samples and shipping arrangements.
Absolutely. We offer OEM/ODM services including custom packaging, branding, and product development tailored to your specifications.
Links
Contact Us