Views: 0 Author: Site Editor Publish Time: 2026-11-23 Origin: Site
Proximal femoral nail antirotation (PFNA) is a commonly used intramedullary fixation system for treating certain proximal femoral fractures, particularly intertrochanteric fractures.
One of the most important steps during PFNA surgery is establishing the correct entry point and inserting the main guidewire into the femoral medullary canal. Successful guidewire placement provides the foundation for subsequent canal preparation and nail insertion.
Although guidewire insertion may appear straightforward, it can be technically challenging. Surgeons sometimes encounter repeated unsuccessful attempts because the guidewire cannot be advanced along the intended trajectory.
This problem can be particularly noticeable in patients with obesity or when the patient's positioning does not provide sufficient access to the greater trochanter.
In these situations, the guidewire may approach the femur from an excessively lateral direction, making it difficult to align the entry trajectory with the intended femoral canal axis.
Simply pushing the protection sleeve or soft-tissue sleeve medially may not always solve the problem.
This article discusses the importance of the PFNA entry point, common reasons for an insufficient entry angle, and a practical surgical tip using a curved clamp to help improve medial access.
The entry point determines the initial trajectory of the guidewire and influences the subsequent position of the intramedullary nail.
An incorrectly positioned entry point may make nail insertion difficult and increase the risk of malalignment, cortical damage, or an unfavorable nail trajectory.
The greater trochanter is the usual entry region for most trochanteric-entry proximal femoral nails. However, the exact starting point depends on the design and geometry of the selected implant.
The entry point should be evaluated in both the anteroposterior (AP) and lateral planes.
On the AP view:
The starting point is commonly located at the tip of the greater trochanter or slightly lateral to it, depending on the mediolateral angle of the specific nail system.
On the lateral view:
The starting point should be aligned with the intended axis of the proximal femoral medullary canal. It is commonly located around the central region of the greater trochanter in the anterior-posterior direction, although the precise position depends on the implant design.
Some surgical descriptions divide the greater trochanter into three sections to help identify the starting point. Such divisions should be regarded as practical anatomical references rather than universal rules for every nail system.
Important: Always follow the manufacturer's surgical technique for the selected PFNA or cephalomedullary nail. The AP and lateral views must both confirm an appropriate entry trajectory before opening the femoral canal.
During routine surgery, the surgeon needs to establish a trajectory that allows the guidewire to enter the greater trochanter and advance into the femoral medullary canal.
However, several factors may restrict the available working angle.
In patients with substantial soft-tissue thickness around the hip, the distance between the skin surface and the greater trochanter is increased.
This can create several technical difficulties:
The guidewire and protection sleeve must pass through a thicker soft-tissue envelope.
The surgeon may have difficulty bringing the instrument sufficiently close to the femur.
The soft tissues may push the sleeve away from the intended trajectory.
The guidewire may approach the greater trochanter from an excessively lateral direction.
As a result, the surgeon may find it difficult to align the guidewire with the intended axis of the femoral canal.
Patient positioning is another important factor.
During proximal femoral nailing on a fracture table, the injured hip generally needs sufficient adduction to provide access to the greater trochanter.
If the torso and pelvis are not positioned appropriately, the operative hip may remain relatively abducted, making it difficult to establish the desired entry trajectory.
In some cases, tilting the patient's torso approximately 10–15 degrees toward the contralateral side can help facilitate hip adduction and improve access to the entry point.
The exact positioning should be adjusted according to the fracture, patient anatomy, traction setup, and fluoroscopic requirements.
Even when the bony entry point has been correctly identified, the surrounding soft tissues may prevent the protection sleeve from reaching the greater trochanter along the intended trajectory.
This can make the guidewire appear to enter from a more lateral direction than desired.
Repeatedly forcing the sleeve inward may not provide sufficient correction, particularly in patients with a thick soft-tissue envelope.
Before using an additional instrument maneuver, it is important to reassess the basic surgical conditions.
Several factors should be checked.
Confirm that:
The pelvis is appropriately positioned on the fracture table.
The operative hip can be adequately adducted.
The torso is not preventing access to the greater trochanter.
The traction and reduction setup does not cause unwanted pelvic rotation.
The C-arm can obtain reliable AP and lateral views.
Improving patient positioning may provide a better working angle without requiring additional force on the soft tissues.
Confirm that the entry point is appropriate for the selected nail system.
A starting point that is too lateral may force the nail into an unfavorable trajectory and contribute to varus alignment.
The guidewire should be checked under fluoroscopy in both AP and lateral views. Correct alignment in only one projection is insufficient.
When the soft-tissue envelope prevents the protection sleeve from reaching the intended position, reassess the incision and the access path.
In patients with obesity, a sufficiently long incision and appropriate soft-tissue exposure may be necessary.
Avoid relying on excessive force to push the sleeve through the soft tissues. The objective is to establish a controlled trajectory rather than simply increase the pressure applied to the instruments.
When the entry angle remains insufficient despite appropriate positioning and adjustment of the protection sleeve, an additional instrument maneuver may help.
One practical technique is to use the jaws of a curved clamp to assist with medial displacement of the soft tissues around the entry region.
The purpose of this maneuver is to reduce the soft-tissue obstruction between the skin incision and the intended bony entry point, helping create a more favorable working angle for guidewire insertion.
In patients with a thick soft-tissue envelope, the guidewire and sleeve may be restricted by the surrounding tissue.
A curved clamp provides an alternative way to manage the soft tissues around the entry region.
By using the curved jaws to facilitate medial soft-tissue displacement, the surgeon may obtain better access to the intended entry trajectory.
This can help reduce the tendency for the guidewire to approach the greater trochanter from an excessively lateral direction.
The purpose of the curved-clamp maneuver is to improve soft-tissue access, not to compensate for an incorrect bony entry point.
After adjusting the soft tissues, the surgeon should reassess:
Whether the protection sleeve can reach the intended entry region.
Whether the guidewire trajectory is appropriate on the AP view.
Whether the guidewire remains aligned with the medullary canal on the lateral view.
Whether the planned nail trajectory is compatible with the selected implant system.
The guidewire should only be advanced when the entry point and trajectory are satisfactory under fluoroscopic control.
Technical note: The exact position, direction, and degree of clamp manipulation depend on the surgical approach, anatomy, and instrument configuration. The maneuver should be performed by an appropriately trained surgeon under direct visualization and with care to avoid soft-tissue or neurovascular injury. It should not be interpreted as a substitute for correct entry-point selection.
Even when the entry angle appears satisfactory, several technical problems can affect guidewire placement.
A lateral starting point may direct the nail toward the lateral cortex and contribute to varus malalignment.
The entry point should be checked against the intended implant trajectory before opening the canal.
A guidewire may appear correctly positioned on the AP image while being too anterior or posterior on the lateral image.
Both views are necessary to evaluate the guidewire's relationship to the femoral canal.
Forceful advancement may damage soft tissues or make it difficult to maintain the intended trajectory.
If the sleeve cannot reach the correct position, reassess the incision, soft-tissue access, and patient positioning rather than repeatedly forcing it inward.
Different proximal femoral nail systems have different mediolateral angles and proximal geometries.
A starting point that is appropriate for one nail may not be appropriate for another.
Always consult the relevant manufacturer's surgical technique.
For many trochanteric-entry PFNA systems, the starting point is located at the tip of the greater trochanter or slightly lateral to it on the AP view. Its anterior-posterior position should be assessed on the lateral view according to the specific implant design.
Possible reasons include excessive soft-tissue thickness, inadequate hip adduction, an unfavorable incision or sleeve trajectory, and an incorrect starting point.
The surgeon should reassess patient positioning, soft-tissue access, and fluoroscopic alignment before repeating guidewire insertion.
It can. Increased soft-tissue thickness may restrict the working angle and make it harder to position the protection sleeve close to the greater trochanter.
Appropriate positioning, adequate exposure, and careful soft-tissue management can help address these difficulties.
Medial pressure on the protection sleeve may help in some cases, but it may not be sufficient when the soft-tissue envelope is thick or the patient's position restricts access.
The underlying cause should be identified before applying additional force.
The AP view helps assess the mediolateral trajectory and the relationship between the guidewire and the proximal femur.
The lateral view helps identify anterior or posterior deviation and confirms whether the guidewire follows the intended medullary canal axis.
Using both views reduces the risk of accepting an incorrect trajectory based on a single fluoroscopic projection.
Correct guidewire insertion is a critical step during PFNA and other proximal femoral intramedullary nailing procedures.
In patients with obesity or restricted operative access, the guidewire may approach the greater trochanter from an excessively lateral direction, making it difficult to achieve the intended entry angle.
Before attempting additional instrument maneuvers, surgeons should reassess patient positioning, hip adduction, the incision, soft-tissue access, and the implant-specific entry point.
When soft-tissue obstruction remains a problem, a curved clamp may be used as a practical aid to facilitate medial soft-tissue displacement and improve access to the intended guidewire trajectory.
Ultimately, the goal is not simply to make guidewire insertion easier. It is to establish an anatomically appropriate entry point and a guidewire trajectory that is confirmed in both AP and lateral fluoroscopic views.
Femoral Intramedullary Nail Entry Angle: Tips for Difficult Guidewire Insertion
How To Identify Scoliosis: Adams Forward Bend Test And Clinical Signs
Light Bulb Sign in Posterior Shoulder Dislocation: Radiographic Features and Diagnosis
Hook of Hamate Fracture: Symptoms, Diagnosis, Classification, and Treatment
Chronic Ankle Instability: Symptoms, Causes, Diagnosis, and Treatment
ACL Reconstruction: Surgery, Graft Options, Symptoms, and Recovery
Fracture Blisters: Management, Treatment, and Timing of Fracture Surgery
Rotator Cuff Tear: Symptoms, Causes, Treatment, and Recovery
Meniscus Tear: Should You Choose Conservative Treatment or Surgery?
Arthroscopic Knot Tying Techniques: 6 Common Sliding and Locking Knots
Links
Contact Us