Made from Grade TC4 titanium alloy, CERVINO Anterior Cervical Plates are offered in multiple hole configurations (4‑, 6‑, or 8‑hole plates) and lengths (e.g. 22.5 mm to 81 mm). The system accepts self‑tapping or self‑drilling screws in various lengths, with a robust locking mechanism to resist screw back‑out. Large graft windows support visualization during implantation. Sterile-packed and CE- and ISO-certified, it supports single- to multi-level constructs in anterior cervical stabilization.
2002-0101
TOOLMED
TC4
1 Pcs
5-15 Days
/
| Availability: | |
|---|---|
Product Description
Plates available in 4-, 6-, and 8-hole configurations, lengths from ~22 mm to 81 mm
Ti‑6Al‑4V alloy construction for biocompatibility and fatigue strength
Low-profile thickness (~2.0–2.5 mm) reduces soft-tissue irritation
Large graft windows enable direct endplate visibility for optimal graft placement
Self‑tapping and self‑drilling screws (13–17 mm length), color-coded for identification
Intuitive locking mechanism provides tactile feedback upon closure
Compatible with constrained, semi‑constrained or hybrid screw trajectories
Available OEM/ODM; consistent quality under CE 0123, ISO 13485, ISO 9001, and GMP systems
CERVINO plates are intended for anterior cervical vertebral stabilization in adult patients post-ACDF, including:
Single- to multi-level fusion (up to C2–T1)
Conditions such as degenerative disc disease, radiculopathy, myelopathy, spondylosis
Trauma, tumor, deformity, pseudoarthrosis, or prior fusion failures
Temporary internal fixation during fusion period

| Product Name | CERVINO Anterior Cervical Plate |
| Material | TC4 |
| Certificate | CE Certificate |
| Brand | TOOLMED |
| MOQ | 1 Pcs |
| OEM | Avaliable |
| Package | PE Inner Bag+Carton |
| Payment Method | T/T,Bank transfer, Western Union |
| Delivery Time | 5-15 Days |
| Shipping | DHL EMS UPS TNT FEDEX |



A rigid anterior cervical fixation device for ACDF that uses a low-profile titanium plate affixed via screws through constrained or semi-constrained screw holes, secured by an integrated locking mechanism. It supports anterior spinal stabilization while reducing profile and facilitating graft visualization.
The CERVINO™ Anterior Cervical Plate is indicated for use in:
Stabilization during ACDF for degenerative, trauma, tumor, or revision cases
Single to multi-level procedures (C2–T1) using plates tailored by hole count and length
Restoration of cervical lordosis with pre-contoured or manually contoured plates
Cases requiring clear graft visualization and easy screw insertion workflow
Low-profile architecture minimizes postoperative dysphagia and esophageal irritation
Generous graft viewing window facilitates proper graft placement and assessment
Versatile screw options (self‑tapping or drilling) enhance surgical efficiency
Secure, tactile locking mechanism ensures stable fixation and prevents back‑out
Availability in multiple sizes supports simple selection across varied surgical needs
Manufactured to high quality standards, with OEM/ODM flexibility
Anterior cervical plates are well-documented to provide immediate mechanical stability post-ACDF, reduce risk of graft settling and pseudarthrosis, and support lordotic alignment. Plate-level locking mechanisms and screw stability reduce screw loosening risk. Low-profile design also mitigates soft-tissue complications.
Perform standard Smith-Robinson anterior approach to expose affected levels
After decompression and graft insertion, select appropriate CERVINO plate size (hole count and length)
Confirm flush contact between plate and vertebral bodies; contour plate if necessary (avoiding bending over locking slots)
Temporarily fix plate with tacks or pins at superior/inferior ends if needed
Insert screws through plate holes—self‑drilling or tapping technique per preference
Once all screws are seated, rotate locking mechanism (typically 180°) until a “click” confirms full engagement
Remove temporary tacks and confirm final construct with fluoroscopy
Avoid repeated or excessive plate bending to prevent crack or structural weakness
Following implantation, proper postoperative care is essential to ensure healing and prevent complications:
Immediate postoperative radiographs to confirm implant positioning and graft placement
Encourage early mobilization with cervical collar support per surgeon’s protocol
Monitor for dysphagia, hoarseness, or hardware prominence during early follow-ups
Initiate rehabilitation focusing on cervical stability and avoiding hyperextension
Conduct periodic imaging to assess fusion progress and implant integrity
The CERVINO Anterior Cervical Plate provides a robust, versatile solution for ACDF and anterior cervical stabilization, combining low profile, reliable locking, and anatomical flexibility. Manufactured from titanium alloy and compliant with CE, ISO 13485/9001, it supports efficient placement and enhanced construct stability. With a variety of plate lengths, screw options, and graft window visibility, it aligns with modern surgical demands.
Yes—but bending should be gentle and limited to areas away from the locking mechanism slots to avoid structural damage. Only contour as needed for anatomical fit.
Both self‑tapping and self‑drilling screws are available (13‑17 mm). Self‑drilling screws eliminate the need for pilot holes, streamlining the procedure.
Rotate the locking cap or plate segment until a tactile “click” confirms engagement. This mechanism secures screw heads and prevents back‑out. Designed to be locked a maximum of two times.
Yes—large central windows in the plate allow visualization of graft placement during and after insertion.
Yes—4, 6, and 8 hole versions support single- through multi‑level fusion, up to C2–T1.
Our factory is equipped with over 60 advanced CNC machines operated by 100+ skilled technicians, a 300 m² GMP-compliant clean room, and a 10,000 m² production facility. We maintain a CNAS and ISO 17025 certified testing center, invest heavily in CNC turning technology, and utilize high-precision inspection systems including CMM, PP, and QV to ensure product quality and consistency.


We offer fast and reliable global shipping. Standard lead times range from 7 to 15 working days, depending on order quantity and customization requirements. Express delivery options are also available upon request.
Yes, we ship to most countries worldwide. We work with trusted logistics partners to ensure timely and secure delivery.
We accept a variety of payment options, including T/T (bank transfer), L/C, and PayPal for smaller orders. Payment terms can be discussed based on order volume and partnership agreements.
Yes, samples are available for evaluation. Please contact our sales team to request product samples and shipping arrangements.
Absolutely. We offer OEM/ODM services including custom packaging, branding, and product development tailored to your specifications.
Links
Contact Us