The ATLAS 5.5 Reduction Polyaxial Pedicle Screw is engineered to support surgeons in achieving precise spinal realignment and reduction. Its extended tab design simplifies rod capture in challenging anatomical scenarios, while the polyaxial head enables angulation for ideal alignment. Manufactured from biocompatible titanium alloy, this system supports 5.5 mm rods and ensures a firm, secure hold during correction maneuvers. Its high pull-out strength, intuitive reduction capability, and compatibility with minimally invasive approaches make it a versatile solution for complex thoracolumbar fixation.
2306-0101
TOOLMED
TC4
1 Pcs
5-15 Days
/
| Availability: | |
|---|---|
Product Description
StarDrive recess improves torque control for set screw insertion.
Extended reduction tabs with notches simplify rod reduction and facilitate break‑off.
Dual‑lead thread geometry enhances screw purchase and insertion efficiency.
Tapered tip enables accurate pedicle access and bicortical fixation.
±22° variable polyaxial angulation improves rod alignment in deformity cases.
Color-coded sizes aid intraoperative identification.
Low-profile head reduces soft tissue irritation during lying and surgery.
ATLAS 5.5 Reduction Polyaxial Pedicle Screw is intended for adult thoracolumbar spinal stabilization in clinical scenarios including:
Degenerative spinal disease
Vertebral fractures
Spondylolisthesis
Deformity correction (e.g. scoliosis, kyphosis)
Spinal tumors and fusion procedures

| Product Name | ATLAS 5.5 Reduction Polyaxial Pedicle Screw |
| Material | TC4 |
| Certificate | CE Certificate |
| Brand | TOOLMED |
| MOQ | 1 Pcs |
| OEM | Avaliable |
| Package | PE Inner Bag+Carton |
| Payment Method | T/T,Bank transfer, Western Union |
| Delivery Time | 5-15 Days |
| Shipping | DHL EMS UPS TNT FEDEX |


A reduction polyaxial pedicle screw combines traditional screw anchorage with integrated reduction mechanisms, allowing gradual, controlled repositioning of spinal vertebrae. It is especially valuable in procedures requiring vertebral realignment, such as scoliosis correction, traumatic dislocations, and kyphotic deformities. The "polyaxial" function permits the screw head to pivot in multiple directions, enabling easier rod placement even in complex anatomical structures.
Spinal deformity corrections (e.g., scoliosis, kyphosis)
Traumatic fractures and dislocations
Revision surgeries requiring vertebral repositioning
Complex thoracolumbar stabilization
Allows precise, controlled reduction without compromising screw integrity
Reduces surgical time by simplifying rod insertion
Enhances correction of spinal alignment with stable fixation
Supports open and minimally invasive procedures
Break-off tabs ensure low-profile final construct
The design features a ball‑and‑socket polyaxial interface to accommodate rod contouring, while the dual‑lead threads reduce insertion torque and distribute compression effectively. The tapered tip supports safe pedicle entry and strong bicortical fixation.
Preoperative Planning: Evaluate imaging to select appropriate screw size and trajectory.
Screw Insertion: Place the pedicle screw using a freehand or navigated technique to ensure accurate pedicle entry and trajectory.
Rod Placement and Reduction: Use the reduction tabs to gradually guide the rod into the screw heads, facilitating controlled vertebral realignment.
Locking the Construct: Insert and tighten set screws to lock the rod and screws into a stable construct.
Tab Removal: Break off the reduction tabs cleanly after locking to minimize implant profile.
Final Verification: Use fluoroscopy or X-ray imaging to confirm correct implant positioning and construct stability.
Following implantation, proper postoperative care is essential to ensure healing and prevent complications:
Restrict bending, twisting, and heavy lifting during initial recovery to protect the implant site.
Schedule regular follow-up imaging to monitor fusion progress and hardware integrity.
Manage pain with prescribed analgesics and address any discomfort promptly.
Initiate supervised physical therapy focusing on gradual restoration of mobility and strength.
Vigilantly monitor for signs of infection or complications and report any abnormal symptoms immediately.
The ATLAS 5.5 Reduction Polyaxial Pedicle Screw combines innovative reduction technology with proven polyaxial fixation principles. It provides surgeons with enhanced control during complex spinal deformity and trauma surgeries, improving patient outcomes through precise vertebral realignment and durable implant stability. Manufactured to international quality standards, it supports both open and minimally invasive surgical techniques, making it a versatile and reliable choice in modern spinal care.
The integrated extended reduction tabs allow gradual rod engagement and vertebral realignment, providing improved control during complex deformity corrections.
Yes, it is compatible with 5.5 mm rods made of titanium or cobalt chrome, offering flexibility in construct design based on clinical needs.
The head offers ±25° to ±30° of motion, making rod seating easier and enhancing construct adaptability.
Absolutely. Its strong fixation and reduction features make it ideal for revision cases involving failed constructs or deformity progression.
Yes, the reduction screw can be adapted to both open and minimally invasive techniques, particularly when rod insertion is difficult due to anatomical challenges.
Our factory is equipped with over 60 advanced CNC machines operated by 100+ skilled technicians, a 300 m² GMP-compliant clean room, and a 10,000 m² production facility. We maintain a CNAS and ISO 17025 certified testing center, invest heavily in CNC turning technology, and utilize high-precision inspection systems including CMM, PP, and QV to ensure product quality and consistency.


We offer fast and reliable global shipping. Standard lead times range from 7 to 15 working days, depending on order quantity and customization requirements. Express delivery options are also available upon request.
Yes, we ship to most countries worldwide. We work with trusted logistics partners to ensure timely and secure delivery.
We accept a variety of payment options, including T/T (bank transfer), L/C, and PayPal for smaller orders. Payment terms can be discussed based on order volume and partnership agreements.
Yes, samples are available for evaluation. Please contact our sales team to request product samples and shipping arrangements.
Absolutely. We offer OEM/ODM services including custom packaging, branding, and product development tailored to your specifications.
Links
Contact Us