Synthes External Fixator Instrument Set-III 5400-03
TOOLMED
/
/
/
1 Pcs
5-7 days
| Availability: | |
|---|---|
Product Description
The Generation-III wrenches feature a narrower head design compared to predecessors, allowing the surgeon to easily access and tighten clamps in dense constructs where space between rods is minimal.
Equipped with advanced T-handle drivers that support rapid pin attachment and release, streamlining the process of percutaneous pin placement and reducing overall surgical time.
Includes a new series of hardened drill sleeves that provide superior guidance for trocar and drill bit entry, protecting soft tissue while ensuring perfect bicortical bone penetration.
Instruments feature a matte, anti-glare finish to reduce reflection under bright operating room lights, improving visual clarity for the surgeon during critical fracture reduction steps.
Used to construct rigid external frames for the immediate management of comminuted long bone fractures and pelvic disruptions in polytrauma patients.
Indicated for the stabilization of the knee, ankle, or elbow joint following severe fracture-dislocations to maintain length and alignment while protecting soft tissues.
Provides the high-precision tools necessary for the maintenance of distraction and reduction in open fractures until definitive internal fixation or secondary healing is possible.


| Product name | Synthes External Fixator Instrument Set-III 5400-03 |
| Material | TA3 |
| Diameter | / |
| Length | / |
| Application | / |
| Certificate | CE Certificate |
| Brand | TOOLMED |
| MOQ | 1 Pcs |
| OEM | Avaliable |
| Package | PE Inner Bag+Carton |
| Payment Method | T/T,Bank transfer, Western Union |
| Delivery Time | 5-7 days |
| Shipping | DHL EMS UPS TNT FEDEX |


The 5400-03 Instrument Set is the premium "command center" of surgical tools for trauma reconstruction. It contains the refined wrenches, drivers, and guides needed to assemble complex "scaffolding" around a patient's limb. The Set-III is distinguished by its lightweight, high-torque wrenches that allow surgeons to exert immense locking force with less effort, ensuring the fixator stays rigid under physiological load.
This set is essential in Level-1 trauma centers for treating the most catastrophic orthopedic injuries. It is the toolset of choice for "pelvic binders," tibia bridging, and pilon fracture stabilization. Its slim-profile components are especially useful when many bars and clamps are required close together to support multiple fracture lines.
The core advantage of the Generation-III set is ergonomic efficiency. Every gram of weight saved and every millimeter trimmed from the wrench heads translates to faster surgery and less fatigue for the trauma team. In critical situations where time is life, the 5400-03 set allows for a more intuitive, "snappier" assembly process than older, bulkier sets.
The instruments in this set are geared towards achieving absolute rigidity. Biomechanically, the wrenches must ensure that fixator clamps exert enough pressure to stop rod-pin slipping. The Set-III drivers ensure that bone pins are anchored without wobble, which is vital for the frame to act as a load-sharing device that allows the patient to eventually heal without frame failure.
Using the set's precision trocar and sleeves, the surgeon drills into the bone. The quick-release T-handle then inserts the pin. Modular wrenches are then used to tighten rod-to-rod or pin-to-rod clamps. The surgeon can then perform "active reduction," using the mechanical leverage of the 5400-03 wrenches to pull the bone into perfect alignment before final tightening.
While the set is cleaned and sterilized for the next patient, the stability it provided remains with the patient. Post-op, clinical staff check the construct periodically. Because the Set-III facilitates such a tight initial lock, clinical follow-ups often show less "construct drift," leading to fewer intra-clinic adjustments compared to frames built with standard tools.
The Synthes External Fixator Instrument Set-III 5400-03 is the standard of excellence for trauma surgery. Its blend of high-strength surgical steel, refined ergonomics, and slim design provides surgeons with the ultimate confidence to handle complex fractures, ensuring the patient has a rock-solid foundation for biological recovery.
Yes. The slim-profile heads are particularly beneficial for ankle and joint spanning where space is limited and multiple rods converge in a small anatomical area.
Yes, modern sets like the 5400-03 typically feature labeled or silhouetted slots in the tray to ensure every tool is returned and accounted for before closing the wound.
Some wrenches in the Set-III utilize a modular head design where different socket sizes can be swapped onto the same handle, maximizing functionality while minimizing the weight and footprint of the surgical tray.
Instruments must be manually scrubbed with enzymatic cleaners, rinsed, and then placed through a certified washer-disinfector cycle before high-pressure steam sterilization (autoclaving).
This set is primarily for large (Tibia/Femur) and small fragment (Forearm/Ankle) fixation. Ultra-mini finger fixators typically require their own specialized micro-instrumentation set.


We offer fast and reliable global shipping. Standard lead times range from 7 to 15 working days, depending on order quantity and customization requirements. Express delivery options are also available upon request.
Yes, we ship to most countries worldwide. We work with trusted logistics partners to ensure timely and secure delivery.
We accept a variety of payment options, including T/T (bank transfer), L/C, and PayPal for smaller orders. Payment terms can be discussed based on order volume and partnership agreements.
Yes, samples are available for evaluation. Please contact our sales team to request product samples and shipping arrangements.
Absolutely. We offer OEM/ODM services including custom packaging, branding, and product development tailored to your specifications.
Links
Contact Us